What a Compliant Victorian Small Second Dwelling Actually Needs

A plain-English guide to the liveable housing and 7-star energy rules in Victoria

So the rules have changed and your Small Second Dwelling can now be up to 80 m². The next question is the one that actually shapes your build: what does the building itself have to include?

There are two sets of rules, and both are compulsory. The first is about making the home easy for anyone to live in — including someone with a pram, a walking frame or a wheelchair. The second is about how much energy it uses. Get either one wrong and you’ll be fixing it later, at your cost.

Don’t worry if the terms below are new to you. That’s exactly what this guide is for.

A Small Second Dwelling is classified as a Class 1a building — that’s the building code’s name for a single home on its own block. Because of that, it has to follow the Livable Housing Design Standard. In practice, that comes down to six things.

There has to be a continuous route from the street, your garage or your parking space to the front door, with no steps along the way.

What that means in practice: the path needs to be a gentle slope — no more than 1 metre of rise for every 14 metres of length, and gentler still over longer distances at 1 metre for every 20. It needs at least 1 metre of clear width, with a flat landing at each end of any ramp.

Why it matters: this is the difference between a visitor in a wheelchair being able to get to your door, and being stuck at the letterbox.

At least one door has to be level with the ground outside it, so prams, wheelchairs and walking frames can get through without being lifted.

What that means in practice: the doorway needs a clear opening of at least 820 mm — wide enough for a standard wheelchair. The threshold under the door has to be flush, or no more than 5 mm high, which is roughly the thickness of a five-cent coin.

Once you’re inside, you need to be able to get from room to room on the ground floor without squeezing.

What that means in practice: internal doors need a clear opening of at least 820 mm, and hallways need to be at least 1 metre wide between the walls.

At least one toilet has to be on the entry level, so nobody has to manage stairs.

What that means in practice: there needs to be a clear space in front of the toilet of at least 1200 mm long by 900 mm wide — enough room to turn a wheelchair or park a walking frame. That space has to stay completely clear, and the most common thing that eats into it is the bathroom door swinging inward.

Why it matters: this is the detail that catches people out most often, and it’s much cheaper to plan for than to fix.

At least one bathroom on the entry level needs a shower with no step up and no raised tray — you walk straight in.

What that means in practice: the shower floor should flow into the bathroom floor, with any lip or edge no more than 5 mm high.

Why it matters: no trip hazard, and no lifting your legs over a tray.

The walls around the toilet, shower and bath have to be built so grab rails can be added later without pulling the room apart.

What that means in practice: the framing inside those walls needs extra reinforcement — 12 mm structural plywood, 25 mm timber noggings (the horizontal timber pieces between studs), or steel framing plates.

Why it matters: adding a grab rail later is then a ten-minute job, not a renovation.

Under the National Construction Code (NCC 2022), any new Small Second Dwelling in Victoria needs a minimum 7-star NatHERS rating.

What that means in practice:NatHERS is the Nationwide House Energy Rating Scheme. It scores a home out of 10 for how well it holds its temperature through the year. Seven stars is the minimum — the higher the score, the less heating and cooling you need, and the lower your bills.

Victoria is a cool climate — Melbourne and surrounds sit in what the code calls Zone 6, and inland and alpine areas are colder still in Zone 7. So the rules focus on keeping heat in. To reach 7 stars, insulation has to wrap the whole building continuously, like a blanket with no gaps. These are the minimum levels to design to.

R4.0 to R6.0, depending on your roof style and colour.

What that means in practice: “R” is simply a measure of how well a material resists heat passing through it — a higher number means better insulation. The critical rule is that the layer must be unbroken. If your ceiling steps down partway across, the insulation has to follow it down the side, otherwise heat leaks through that gap.

R2.5 to R2.7.

What that means in practice: the insulation batts need to fit snugly with no gaps, and the spaces around every window and door frame need to be packed out too. Gaps around frames are one of the most common causes of draughts and lost heat.

R2.0 to R2.5, but only if the dwelling sits on a raised timber or steel floor rather than a concrete slab on the ground.

What that means in practice: a raised floor has cold air underneath it, so it needs its own insulation. A concrete slab doesn’t.

All insulation must meet the Australian standard AS/NZS 4859, and reflective membranes must meet AS 4200.1.

What that means in practice: your builder should be able to show you the product certification. This is one of the reasons cheap imported materials are a false economy — if they don’t carry the certification, they don’t count.

Insulation also can’t touch anything hot. There has to be a safe gap around downlights, heater flues and electrical transformers.

Insulation is only half the story. Victoria also enforces a whole-of-home energy budget, which means the fixed equipment in your dwelling — heating and cooling, hot water and lighting — has to balance out too.

What that means in practice: even a well-insulated home can fall short if it’s fitted with cheap, inefficient appliances. Most projects get there with a high-efficiency heat pump for hot water, or a small rooftop solar array.

Why it matters: this is a design decision, not something to bolt on at the end. Planning for it from the start costs far less than retrofitting it.

None of this is unusual, but all of it is specific — and it’s exactly where cheap imported designs and kit packages fall down. A dwelling designed for a different state’s climate, or to the rules as they stood before October 2026, will cost you more to correct than it saved.

Use a builder who knows your area and the Victorian rules. Twelve Star Homes builds with Victorians for Victorians.

If you’d like to talk through what your site can actually accommodate before you commit to anything, we’re happy to have that conversation.

[Book a 15-minute call →]

Twelve Star Homes — small second dwellings for owner-builders across Melbourne.